Buy Industrial Ventilation Fans Online
Industrial Radial Blade Centrifugal Fan provides steady airflow and high pressure for factories, workshops, and commercial spaces. The radial-blade impeller in a compact volute moves air efficiently through long ducts, handling fume extraction, dust removal, and general ventilation. Made from solid steel with a practical grey finish, key connections use corrosion-resistant bolts for durability. Its straightforward layout and built-in mounting brackets make installation simple and secure. Compact, sturdy, and low-maintenance, this centrifugal industrial blower is a reliable choice for a wide range of industrial and commercial air-handling needs.
Type :
Centrifugal FanPayment :
T/TOrder(MOQ) :
1 PCShipping Port :
GuangZhou, FoShanLead Time :
7-15 daysProduct Origin :
ChinaIndustrial Radial Blade Centrifugal Fan
Industrial Radial Blade Centrifugal Fan provides steady airflow and high pressure for factories, workshops, and commercial spaces. The radial-blade impeller in a compact volute moves air efficiently through long ducts, handling fume extraction, dust removal, and general ventilation. Made from solid steel with a practical grey finish, key connections use corrosion-resistant bolts for durability. Its straightforward layout and built-in mounting brackets make installation simple and secure. Compact, sturdy, and low-maintenance, this centrifugal industrial blower is a reliable choice for a wide range of industrial and commercial air-handling needs.
| Model | Power(kW) | Voltage(V) | Volume(m³/h) | Pressure(Pa) | Staticpressure(Pa) |
| 2.0A | 0.18-4P | 380 | 852~1532 | 227~208 | 217~176 |
| 0.25-4P | 380 | 1066~2348 | 251~245 | 213~182 | |
| 0.32-4P | 380 | 1568~3010 | 266~245 | 219~145 | |
| 0.12-6P | 380 | 931~1759 | 110~102 | 92~60 | |
| 0.18-6P | 380 | 1350~2501 | 114~91 | 94~40 | |
| 2.25A | 0.32-4P | 380 | 1304~2090 | 327~320 | 312~282 |
| 0.45-4P | 380 | 2159~3426 | 320~301 | 260~209 | |
| 0.55-4P | 380 | 2387~3976 | 305~254 | 243~151 | |
| 0.18-6P | 380 | 1642~2548 | 160~147 | 137~92 | |
| 0.25-6P | 380 | 1905~3107 | 142~110 | 107~50 | |
| 2.5A | 0.55-4P | 380 | 1373~2577 | 449~470 | 433~427 |
| 0.8-4P | 380 | 2265~4302 | 455~502 | 415~380 | |
| 0.25-6P | 380 | 1576~2770 | 220~250 | 200~198 | |
| 2.8A | 1.1-4P | 380 | 2463~4598 | 398~452 | 367~344 |
| 1.5-4P | 380 | 3504~5866 | 500~422 | 438~258 | |
| 0.37-6P | 380 | 2363~3863 | 241~231 | 213~156 | |
| 0.55-6P | 380 | 2925~4450 | 270~194 | 226~127 | |
| 3.0A | 1.5-4P | 380 | 3071~5520 | 682~750 | 642~649 |
| 0.55-6P | 380 | 2033~4225 | 298~336 | 285~274 | |
| 3.15A | 1.8-4P | 380 | 3041~5565 | 744~836 | 711~741 |
| 2.2-4P | 380 | 4343~6820 | 820~839 | 749~699 | |
| 0.8-6P | 380 | 2875~5408 | 359~353 | 328~265 | |
| 3.55A | 3.0-4P | 380 | 4087~8165 | 952~979 | 915~847 |
| 4.0-4P | 380 | 7424~10913 | 976~938 | 852~703 | |
| 0.8-6P | 380 | 2803~5620 | 407~451 | 388~407 | |
| 1.5-6P | 380 | 4002~8633 | 459~418 | 418~271 | |
| 0.55-8P | 380 | 3301~5646 | 257~248 | 230~185 | |
| 4.0A | 1.5-6P | 380 | 3080~6380 | 552~605 | 539~555 |
| 1.8-6P | 380 | 5088~7526 | 576~656 | 538 587 | |
| 2.2-6P | 380 | 6842~9130 | 632~665 | 568~550 | |
| 1.1-8P | 380 | 4812~6847 | 355~374 | 319~309 | |
| 4.5A | 4.0-6P | 380 | 8437~13617 | 805~868 | 744~708 |
| 5.5-6P | 380 | 11750~18520 | 841~869 | 722~539 | |
| 7.5-6P | 380 | 13710~21500 | 867~881 | 705~483 | |
| 2.2-8P | 380 | 9033~13350 | 462~502 | 410~309 | |
| 5.0A | 6.0-6P | 380 | 11441~20500 | 887~950 | 822~812 |
| 7.5-6P | 380 | 13845~23433 | 938~974 | 841~762 | |
| 4.0-8P | 380 | 11883~18349 | 593~625 | 494~412 |
Key Selling Points
1.Sturdy Radial Blade Structure
The industrial centrifugal fan uses a solid radial-blade impeller that generates strong static pressure, making it suitable for tasks where airflow must travel through long ducts or areas with higher resistance.
2.Reliable Steel Construction
Its heavy-gauge steel housing and reinforced volute provide stability and long service life in demanding industrial settings.
3.Simple to Install and Maintain
The square discharge outlet aligns easily with standard duct systems. Key parts are positioned for quick access, helping reduce downtime during routine checks.
4.Smooth, Efficient, and Quiet Airflow
The balanced impeller and well-shaped volute maintain steady airflow with minimal vibration and noise, even under continuous operation. The fan handles a wide temperature range from –20°C to 60°C and can circulate non-flammable, non-corrosive air with dust and particles kept below 100 mg/m³.

Key Features
1.High-pressure radial impeller for restrictive duct routes
2.Heavy-duty steel body for durability and impact resistance
3.Square outlet compatible with standard rectangular ductwork
4.Balanced impeller for stable airflow and reduced operating noise
5.Handles non-flammable, non-corrosive air within –20°C to 60°C
6.Maintains dust and particle levels below 100 mg/m³
7.Industrial-grade bearings and fasteners for extended service life
Applications
1.Factory and workshop ventilation
2.Dust and fume extraction
3.Process air supply
4.Material handling and conveying systems
5.Central air-conditioning and HVAC systems
6.Air purifiers and ventilators
7.General industrial air movement
| Model | L | W | H | L1 | L2 | L3 | L4 | L5 | W1 | W2 | H1 | H2 | H3 | H4 | H5 | OUTLET SIZE | SCREW 4-cxd |
|||||
| A | A1 | A2 | B | B1 | B2 | |||||||||||||||||
| 2.0A | 348 | 390 | 406 | 160 | 220 | 280 | 402 | 348 | 330 | 360 | 162 | 352 | 190 | 374 | 215 | 364 | 332 | 300 | 260 | 228 | 196 | 4-10x20 |
| 2.25A | 372 | 420 | 438 | 170 | 250 | 310 | 432 | 372 | 375 | 405 | 180 | 380 | 206 | 407 | 235 | 409 | 377 | 345 | 277 | 245 | 213 | 4-10x20 |
| 2.5A | 417 | 420 | 484 | 195 | 250 | 310 | 477 | 418 | 375 | 405 | 200 | 422 | 230 | 452 | 262 | 409 | 377 | 345 | 294 | 262 | 230 | 4-10x20 |
| 2.8A | 464 | 450 | 537 | 215 | 340 | 400 | 530 | 465 | 404 | 440 | 222 | 472 | 258 | 505 | 292 | 424 | 392 | 360 | 329 | 297 | 265 | 4-12x24 |
| 3.0A | 496 | 450 | 574 | 227 | 340 | 400 | 568 | 496 | 430 | 465 | 235 | 500 | 275 | 542 | 313 | 449 | 417 | 385 | 351 | 319 | 287 | 4-12x24 |
| 3.15A | 513 | 450 | 592 | 235 | 370 | 430 | 587 | 513 | 426 | 462 | 252 | 525 | 293 | 570 | 330 | 449 | 417 | 385 | 360 | 328 | 296 | 4-12x24 |
| 3.55A | 574 | 540 | 667 | 260 | 370 | 430 | 658 | 574 | 475 | 510 | 238 | 583 | 323 | 635 | 365 | 494 | 462 | 430 | 399 | 367 | 335 | 4-12x24 |
| 4.0A | 657 | 540 | 752 | 300 | 490 | 570 | 748 | 657 | 530 | 565 | 313 | 660 | 363 | 720 | 413 | 549 | 517 | 485 | 418 | 386 | 382 | 4-12x24 |
| 4.5A | 733 | 645 | 845 | 332 | 560 | 640 | 832 | 733 | 600 | 645 | 356 | 745 | 413 | 813 | 470 | 609 | 577 | 545 | 494 | 462 | 430 | 4-12x24 |
| 5.0A | 818 | 700 | 932 | 370 | 560 | 640 | 827 | 818 | 655 | 700 | 390 | 825 | 455 | 900 | 515 | 672 | 640 | 600 | 552 | 520 | 480 | 4-12x24 |
Tags :